日本孔雀peacock

发布时间:2022-6-15 | 杂志分类:其他
免费制作
更多内容

日本孔雀peacock

502 Special Type Test IndicatorsSuper low measuring force E seriesLever dial gauge that is suitable for flaw-free measure of an object under measurement and for measurement of plasticproducts with a low measuring force.A measuring force is 0.05N, 0.1N or less that is lower than a 0.4N measuring force in the conventional dial gauges.Specifications and outer dimensions are the same as those of standard PC and PCN types, except a measuring force.Special Type Test IndicatorsWithout change lever type... [收起]
[展开]
日本孔雀peacock
粉丝: {{bookData.followerCount}}
提供五金工具电子样本,报价单,配件目录等服务。
文本内容
第51页

50

2 Special Type Test Indicators

Super low measuring force E series

Lever dial gauge that is suitable for flaw-free measure of an object under measurement and for measurement of plastic

products with a low measuring force.

A measuring force is 0.05N, 0.1N or less that is lower than a 0.4N measuring force in the conventional dial gauges.

Specifications and outer dimensions are the same as those of standard PC and PCN types, except a measuring force.

Special Type Test Indicators

Without change lever type (CW rotation only)

Change lever type

Graduation: 0.01mm

Range: 0.5mm

PCN-1AE

Graduation: 0.01mm

Range: 0.8mm

PCN-1BE

Graduation: 0.01mm

Range: 1.0mm

PCN-1LE

Graduation: 0.01mm

Range: 0.5mm

PC-1AE

Graduation: 0.01mm

Range: 0.8mm

PC-1BE

Graduation: 0.01mm

Range: 1.0mm

PC-1LE

Graduation: 0.002mm

Range: 0.28mm

PCN-2E

Specifications

● Measuring force 0.05N

● Contact Point No. XN1A-2

● Measuring force 0.1N

● Contact Point No. XP1A-2

● Measuring force 0.1N

● Contact Point No. XP1B-2

● Measuring force 0.1N

● Contact Point No. XP1L-2

(L = 43.0mm)

● Measuring force 0.05N

● Contact Point No. XN1B-2

● Measuring force 0.05N

● Contact Point No. XN1L-2

(L = 42.8mm)

● Measuring force 0.1N

● Contact Point No. XN2-2

Measuring of deviation

on rubber roller

R

With extra low measuring force,

work piece can be measured without

deforming it.

Model Graduation

(mm)

Range

(mm) Reading Measuring force

less than(N)

Accuracy MPE (µm)

10 Scale 1 Rev. Wide-range

Forward accuracy Hysteresis Repeatability

PCN-1AE 0.01 0.5 0 - 25 - 0 5 − 6 4 3 0.05

PCN-1BE 0.01 0.8 0 - 40 - 0 5 − 9 4 3 0.05

PCN-1LE 0.01 1.0 0 - 50 - 0 5 − 10 5 3 0.05

PCN-2E 0.002 0.28 0 - 140 - 0 2 − 4 3 1 0.1

PC-1AE 0.01 0.5 0 - 25 - 0 5 − 6 4 3 0.1

PC-1BE 0.01 0.8 0 - 40 - 0 5 − 9 4 3 0.1

PC-1LE 0.01 1.0 0 - 50 - 0 5 − 10 5 3 0.1

第52页

51

2 Special Type Test Indicators

Non-electrifying & Complete Anti-magnetic Useries

When non-electrifying type of Pic Test or New Pic Test is used,

electric flow is blocked at the ceramic stem, even of a magnetic

stand is electrified. Thus, you can continue your work without

any problem.

The dial face is light blue color and easy to read.

Specifications and outer dimensions are the same as those of

standard PCN types, except the portion of stems.

Special Type Test Indicators

Vertical Vertical

Graduation: 0.01mm

Range: 0.5mm

PCN-1AU

Graduation: 0.01mm

Range: 0.8mm

PCN-1BU

Graduation: 0.01mm

Range: 1.0mm

PCN-1LU

Graduation: 0.002mm

Range: 0.28mm

PCN-2U

Graduation: 0.002mm

Range: 0.2mm

PCN-2BU

Graduation: 0.01mm

Range: 0.5mm

PCN-5U

Graduation: 0.002mm

Range: 0.28mm

PCN-6U

Specifications

Ruby ball

Anti-magnetic

Phosphor bronze pointer

Ceramic Stem

(anti-magnetic)

● Contact Point

No. XN1A-2R

● Contact Point

No. XN2B-2R

Graduation: 0.001mm

Range: 0.14mm

PCN-SU

● High accuracy

● Contact Point

No. XNS-2R

● Contact Point

No. XN1A-2R

● Contact Point

No. XN2-2R

● Contact Point

No. XN1B-2R

● Contact Point

No. XN1-2R

(L=42.8mm)

● Contact Point

No. XN2-2R

Without change lever type (CW rotation only)

Electric discharge

machining

Ceramic stem is supported by a

magnetic stand.

Electric current is isolated by the

ceramic stem.

It is thus possible to measure the

work piece without electrifying it.

Model Graduation

(mm)

Range

(mm) Reading Measuring force

less than(N)

Accuracy MPE (µm)

10 Scale 1 Rev. Wide-range

Forward accuracy Hysteresis Repeatability

PCN-1AU 0.01 0.5 0 - 25 - 0 5 − 6 4 3 0.3

PCN-1BU 0.01 0.8 0 - 40 - 0 5 − 9 4 3 0.3

PCN-1LU 0.01 1.0 0 - 50 - 0 5 − 10 5 3 0.3

PCN-2U 0.002 0.28 0 - 140 - 0 2 − 4 3 1 0.3

PCN-2BU 0.002 0.2 0 - 100 - 0 2 − 4 3 1 0.3

PCN-SU 0.001 0.14 0 - 70 - 0 2 − 4 3 1 0.3

PCN-5U 0.01 0.5 0 - 25 - 0 5 − 6 4 3 0.3

PCN-6U 0.002 0.28 0 - 140 - 0 2 − 4 3 1 0.3

第53页

52

2 Special Type Test Indicators

Large dial face Dseries

The dial plate size of PCN-1A, PCN-1L, PCN-2B, and PCN-S models has been enlarged, with easy reading due to the

lager scale spacing, as a result.

Screw type long stems are standard for these large dial face test indicators.

Special Type Test Indicators

Graduation: 0.01mm

Range: 0.5mm

PCN-1AD

Graduation: 0.01mm

Range: 1mm

PCN-1LD

Graduation: 0.002mm

Range: 0.2mm

PCN-2BD

Specifications

● Contact Point No. XN1A-2 ● Contact Point No. XN1L-2

(L = 42.8mm)

● High accuracy

● Contact Point No. XN2B-2

● Contact Point No. XN2B-2

Without change lever type (CW rotation only)

Easy to read

An enlarge dial face with bigger scale

intervals enables easy reading by

Graduation: 0.001mm user of all ages. Range: 0.2mm

PCN-SD

Model Graduation

(mm)

Range

(mm) Reading Measuring force

less than(N)

Accuracy MPE (µm)

10 Scale 1 Rev. Wide-range

Forward accuracy Hysteresis Repeatability

PCN-1AD 0.01 0.5 0 - 25 - 0 5 − 6 4 3 0.3

PCN-1LD 0.01 1.0 0 - 50 - 0 5 − 10 5 3 0.3

PCN-2BD 0.002 0.2 0 - 100 - 0 2 − 4 3 1 0.3

PCN-SD 0.001 0.2 0 - 100 - 0 2 − 4 3 1 0.3

φ46.5

30

φ6 Stem

Large Size Dial Face

第54页

53

2

Lever Type Dial Indicators PIC TEST

Change lever type PCseries

● Miniature Bearing Used

The miniature bearing used as a bearing at the pivot of

the contact point to show good indication stability

without any effect by rod play.

● O-ring used

Oil resistance is enhanced by seating the O-ring in the

turning section of the outer frame.

※ Changes the measuring direction by a change lever.

Lever Type Dial Indicators PIC TEST

Parallel

Parallel

Parallel

Graduation: 0.01mm

Range: 0.5mm

PC-1A

Graduation: 0.01mm

Range: 0.8mm

PC-1B

Graduation: 0.01mm

Range: 0.5mm

PC-3

Graduation: 0.002mm

Range: 0.28mm

PC-4

Graduation: 0.01mm

Range: 1.0mm

PC-1L

Graduation: 0.002mm

Range: 0.28mm

PC-2

Specifications

● Contact Point No. XP1A-2 ● Contact Point No. XP1B-2

● Contact Point No. XP1L-2

(L = 43.0mm)

● Contact Point No. XP2-2

● Contact Point No. XP1A-2

● Contact Point No. XP2-2

Pointer motion

A

M1.7 × 0.35

● Gauge Anti-break Measuring Element.

When a force is applied to the contact point in the lateral

direction, it is bent at the groove of section A to protect

the gauges.

※ The contact point can simply replaced (See page P58).

Graduation: 0.01mm

Range: 1.0mm

PC-3L

● Contact Point No. XP1L-2

New

Model Graduation

(mm)

Range

(mm) Reading Measuring force

less than(N)

Accuracy MPE (µm)

10 Scale 1 Rev. Wide-range

Forward accuracy Hysteresis Repeatability

PC-1A 0.01 0.5 0 - 25 - 0 5 − 6 4 3 0.4

PC-1B 0.01 0.8 0 - 40 - 0 5 − 9 4 3 0.4

PC-1L 0.01 1.0 0 - 50 - 0 5 − 10 5 3 0.4

PC-2 0.002 0.28 0 - 140 - 0 2 − 4 3 1 0.4

PC-3 0.01 0.5 0 - 25 - 0 5 − 6 4 3 0.4

PC-3L 0.01 1.0 0 - 50 - 0 5 − 10 5 3 0.4

PC-4 0.002 0.28 0 - 140 - 0 2 − 4 3 1 0.4

第55页

54

2Special Type Test Indicators

PIC TEST/NEW PIC TEST PC . PCN

PIC TEST/NEW PIC TEST with Ruby ball Contact Point "R" series

● Excellent wear resistance

● Non-electrifying and Anti-magnetic

● Can be used on Electrical Discharge Machine

(Contact Point ball dia. 2mm Only)

Horizontal

Vertical

Specifications

Graduation: 0.01mm

Range: 0.5mm

PC-1AR

● Change Lever type

● Contact Point No. XP1A-2R

Graduation: 0.01mm

Range: 0.8mm

PC-1BR

● Change Lever type

● Contact Point No. XP1B-2R

Graduation: 0.01mm

Range: 1.0mm

PC-1LR

● Change Lever type

● Contact Point No. XP1L-2R

Graduation: 0.002mm

Range: 0.28mm

PC-2R

● Change Lever type

● High accuracy

● Contact Point No. XP2-2R

Graduation: 0.01mm

Range: 0.5mm

PCN-1AR

● Without Change Lever type

● Contact Point No. XN1A-2R

Graduation: 0.002mm

Range: 0.2mm

PCN-2BR

● Without Change Lever type

● High accuracy

● Contact Point No. XN2B-2R

Graduation: 0.01mm

Range: 0.8mm

PCN-1BR

● Without Change Lever type

● Contact Point No. XN1B-2R

Graduation: 0.001mm

Range: 0.14mm

PCN-SR

● Without Change Lever type

● High accuracy

● Contact Point No. XNS-2R

Graduation: 0.01mm

Range: 1.0mm

PCN-1LR

● Without Change Lever type

● Contact Point No. XN1L-2R

Graduation: 0.01mm

Range: 0.5mm

PCN-5R

● Without Change Lever type

● Contact Point No. XN1A-2R

Graduation: 0.002mm

Range: 0.28mm

PCN-2R

● Without Change Lever type

● High accuracy

● Contact Point No. XN2-2R

Graduation: 0.002mm

Range: 0.28mm

PCN-6R

● Without Change Lever type

● High accuracy

● Contact Point No. XN2-2R

Ruby ball Contact Point

Model Graduation

(mm)

Range

(mm) Reading Measuring force

less than(N)

Accuracy MPE (µm)

10 Scale 1 Rev. Wide-range

Forward accuracy Hysteresis Repeatability

PC-1AR 0.01 0.5 0 - 25 - 0 5 − 6 4 3 0.4

PC-1BR 0.01 0.8 0 - 40 - 0 5 − 9 4 3 0.4

PC-1LR 0.01 1.0 0 - 50 - 0 5 − 10 5 3 0.4

PC-2R 0.002 0.28 0 - 140 - 0 2 − 4 3 1 0.4

PCN-1AR 0.01 0.5 0 - 25 - 0 5 − 6 4 3 0.3

PCN-1BR 0.01 0.8 0 - 40 - 0 5 − 9 4 3 0.3

PCN-1LR 0.01 1.0 0 - 50 - 0 5 − 10 5 3 0.3

PCN-2R 0.002 0.28 0 - 140 - 0 2 − 4 3 1 0.3

PCN-2BR 0.002 0.2 0 - 100 - 0 2 − 4 3 1 0.3

PCN-SR 0.001 0.14 0 - 70 - 0 2 − 4 3 1 0.3

PCN-5R 0.01 0.5 0 - 25 - 0 5 − 6 4 3 0.3

PCN-6R 0.002 0.28 0 - 140 - 0 2 − 4 3 1 0.3

New

第56页

2Special Type Test Indicators

Special Type Test Indicators

Without fixed Stem "V" series

● Without fixed stem

This is suited for users, who do not mount the indicator by fixed

Stem.

● Dovetail Stems are available

Mount the indicator by Dovetail on 3 positions on the body. Dovetail

Stem, DS-4 (φ4), DS-6 (φ6) and DS-8 (φ8) are available as

optional accessories.

● Miniature Bearing used

The miniature bearing used as a bearing at the pivot of the contact

point to show good indication stability.

● Contact Point for Gauge anti-breakage

All of our pic test indicator has gauge anti-breakage contact point.

● 0-ring used

Oil resistance is enhanced by seating the 0-ring between inner and

outer frames.

Graduation: 0.01mm

Range: 0.5mm

PC-1AV

● Change Lever type

● Contact Point No. XP1A-2

Graduation: 0.01mm

Range: 0.8mm

PC-1BV

● Change Lever type

● Contact Point No. XP1B-2

Graduation: 0.01mm

Range: 1.0mm

PC-1LV

● Change Lever type

● Contact Point No. XP1L-2

Graduation: 0.002mm

Range: 0.28mm

PC-2V

● Change Lever type

● High accuracy

● Contact Point No. XP2-2

Graduation: 0.01mm

Range: 0.5mm

PCN-1AV

● Without Change Lever type

● Contact Point No. XN1A-2

Graduation: 0.01mm

Range: 0.8mm

PCN-1BV

● Without Change Lever type

● Contact Point No. XN1B-2

Graduation: 0.01mm

Range: 1.0mm

PCN-1LV

● Without Change Lever type

● Contact Point No. XN1L-2

Graduation: 0.002mm

Range: 0.28mm

PCN-2V

● Without Change Lever type

● High accuracy

● Contact Point No. XN2-2

Graduation: 0.002mm

Range: 0.2mm

PCN-2BV

● Without Change Lever type

● High accuracy

● Contact Point No. XN2B-2

Graduation: 0.001mm

Range: 0.14mm

PCN-SV

● Without Change Lever type

● High accuracy

● Contact Point No. XNS-2

55

Specifications

Model Graduation

(mm)

Range

(mm) Reading Measuring force

less than(N)

Accuracy MPE (µm)

10 Scale 1 Rev. Wide-range

Forward accuracy Hysteresis Repeatability

PC-1AV 0.01 0.5 0 - 25 - 0 5 - 6 4 3 0.4

PC-1BV 0.01 0.8 0 - 40 - 0 5 - 9 4 3 0.4

PC-1LV 0.01 1.0 0 - 50 - 0 5 - 10 5 3 0.4

PC-2V 0.002 0.28 0 - 140 - 0 2 - 4 3 1 0.4

PCN-1AV 0.01 0.5 0 - 25 - 0 5 - 6 4 3 0.3

PCN-1BV 0.01 0.8 0 - 40 - 0 5 - 9 4 3 0.3

PCN-1LV 0.01 1.0 0 - 50 - 0 5 - 10 5 3 0.3

PCN-2V 0.002 0.28 0 - 140 - 0 2 - 4 3 1 0.3

PCN-2BV 0.002 0.2 0 - 100 - 0 2 - 4 3 1 0.3

PCN-SV 0.001 0.14 0 - 70 - 0 2 - 4 3 1 0.3

第57页

56

2PIC TEST / NEW PIC TEST PC ・PCN

PIC TEST / NEW PIC TEST PC・PCN

"DS8V" series

● We can provide all of our PIC TEST/NEW PIC TEST with φ8mm

Dovetail Stem to meet with your holding device.

(except Model PC-1BW, PC-1LW)

Example

A

C

Graduation: 0.01mm

Range: 0.8mm

PC-1B-DS8V

Set in Case

Graduation: 0.01mm

Range: 1.0mm

PC-IL-DS8V

Graduation: 0.002mm

Range: 0.28mm

PC-4-DS8V

Graduation: 0.01mm

Range: 0.8mm

PCN-1B-DS8V

Graduation: 0.002mm

Range: 0.28mm

PCN-2-DS8V

Graduation: 0.001mm

Range: 0.14mm

PCN-S-DS8V

A Contact Point end bent at a right has made it possible to make a measurement of an object that used to be

impossible to measure! Set the Contact Point so that it is horizontal and perpendicular to work.

with Contact Point XP1LX-2

The Contact Point enable a measurement of a recessed portion located at the back

of a project portion that would not be possible by the use of an existing Contact Point.

Also makes it possible to measure the

parallelism and run-out of grooves on

diffrent levels.

Contact Point No.

XPILX-2

42.92

φ3

Sφ2

Carbide

9

10

Contact Point Part No. XPILX-2

Right Angle Contact Point for PIC TEST(PAT.No.3065810)

Unique Contact Point not existing before!

dimension

B

第58页

Accessories (Option)

57

2Accessories (Option)

23 57

10

M10x0.5 10

φ10

φ6(φ8)

5

● Replaceable contact point

(carbide ball)

● Pic test holder

● Centricator (Pic Test Indicators supplied on request)

● Dovetail stem

Sφ0.5mm

Sφ0.8mm

Sφ1mm

Sφ2mm (Standard)

Sφ3.0mm

Sφ2.0mm (Ruby ball)

PTH-1

PTH-2

PTH-4

PTH-3

PCD-2

PCD-4

PTH-1・2( )PTH-2

PTH-0

(Head only)

( )PCD-4

PTH-3・4 ( )PTH-4

DS-4

(φ4)

DS-6

(φ6)

DS-8

(φ8) PCD-3

38

12 85.5

106.5(9) 9 11

φ6

φ10

45

32.5

φ25

φ6

90

10

10

10

φ15

60˚

φ8

46.5 15(120)

37.5

1.3

6.35

● Universal holder

● Replaceable contact

point (carbide ball)

Sφ2.0mm (Standard)

Sφ1.0mm

Sφ0.8mm

Sφ0.5mm

Sφ3.0mm

Sφ2.0mm (Ruby ball)

● Dovetail stem

DS-4(φ4 stem)

DS-6(φ6 stem)

DS-8(φ8 stem)

● Pic test holder

PTH-1

PTH-2

PTH-0

● Centricator

PCD-2

● Centricator

PCD-3

PCD-4

● Universal holder

PTH-3(φ6 stem)

PTH-4(φ8 stem)

Standard φ6 stem

φ8

φ6

φ4 φ6 φ8

with fine adjustment

第59页

58

2Dimensions of Lever Type Dial Indicators

Replaceable Contact Points (M1.7 × 0.35)

For Pic Test (Change lever type)

XP1A-3 18.2 3 2.5 PC-1A PC-1AE PC-3

XP1A-2 18.2 2 2.5 PC-1A PC-1AE PC-3

XP1A-2R (ruby ball) 18.2 2 2.5 PC-1A PC-1AE PC-3

XP1A-1 18.2 1 2.5 PC-1A PC-1AE PC-3

XP1A-08 18.2 0.8 2.5 PC-1A PC-1AE PC-3

XP1A-05 18.2 0.5 2.5 PC-1A PC-1AE PC-3

XP1B-3 19.24 3 2.5 PC-1B PC-1BE PC-1BW

XP1B-2 19.24 2 2.5 PC-1B PC-1BE PC-1BW

XP1B-2R (ruby ball) 19.24 2 2.5 PC-1B PC-1BE PC-1BW

XP1B-1 19.24 1 2.5 PC-1B PC-1BE PC-1BW

XP1B-08 19.24 0.8 2.5 PC-1B PC-1BE PC-1BW

XP1B-05 19.24 0.5 2.5 PC-1B PC-1BE PC-1BW

XP1L-3 39.72 3 3.0 PC-1L PC-1LE PC-3L

XP1L-2 39.72 2 3.0 PC-1L PC-1LE PC-3L

XP1L-2R (ruby ball) 39.72 2 3.0 PC-1L PC-1LE PC-3L

XP1L-1 39.72 1 3.0 PC-1L PC-1LE PC-3L

XP1L-08 39.72 0.8 3.0 PC-1L PC-1LE PC-3L

XP1L-05 39.72 0.5 3.0 PC-1L PC-1LE PC-3L

XP2-3 8.80 3 2.2 PC-2 PC-4

XP2-2 8.80 2 2.2 PC-2 PC-4

XP2-2R (ruby ball) 8.80 2 2.2 PC-2 PC-4

XP2-1 8.80 1 2.2 PC-2 PC-4

XP2-08 8.80 0.8 2.2 PC-2 PC-4

XP2-05 8.80 0.5 2.2 PC-2 PC-4

Part No. R(mm) φball (mm) φd(mm) Applicable Indicator

For New Pic Test (without Change lever type)

XN1A-3 17.74 3 2.5 PCN-1A PCN-0 PCN-1AE PCN-1AD PCN-5 PCN-7A

XN1A-2 17.74 2 2.5 PCN-1A PCN-0 PCN-1AE PCN-1AD PCN-5 PCN-7A

XN1A-2R (ruby ball) 17.74 2 2.5 PCN-1A PCN-0 PCN-1AE PCN-1AD PCN-5 PCN-7A PCN-1AU PCN-5U

XN1A-1 17.74 1 2.5 PCN-1A PCN-0 PCN-1AE PCN-1AD PCN-5 PCN-7A

XN1A-08 17.74 0.8 2.5 PCN-1A PCN-0 PCN-1AE PCN-1AD PCN-5 PCN-7A

XN1A-05 17.74 0.5 2.5 PCN-1A PCN-0 PCN-1AE PCN-1AD PCN-5 PCN-7A

XN1B-3 18.63 3 2.5 PCN-1B PCN-1BE PCN-1BZ (A)·(B)

XN1B-2 18.63 2 2.5 PCN-1B PCN-1BE PCN-1BZ (A)·(B)

XN1B-2R (ruby ball) 18.63 2 2.5 PCN-1B PCN-1BE PCN-1BU PCN-1BZ (A)·(B)

XN1B-1 18.63 1 2.5 PCN-1B PCN-1BE PCN-1BZ (A)·(B)

XN1B-08 18.63 0.8 2.5 PCN-1B PCN-1BE PCN-1BZ (A)·(B)

XN1B-05 18.63 0.5 2.5 PCN-1B PCN-1BE PCN-1BZ (A)·(B)

XN1L-3 39.00 3 2.5 PCN-1L PCN-1LE PCN-1LD PCN-1LZ (A)·(B)

XN1L-2 39.00 2 2.5 PCN-1L PCN-1LE PCN-1LD PCN-1LZ (A)·(B)

XN1L-2R (ruby ball) 39.00 2 2.5 PCN-1L PCN-1LE PCN-1LD PCN-1LU PCN-1LZ (A)·(B)

XN1L-1 39.00 1 2.5 PCN-1L PCN-1LE PCN-1LD PCN-1LZ (A)·(B)

XN1L-08 39.00 0.8 2.5 PCN-1L PCN-1LE PCN-1LD PCN-1LZ (A)·(B)

XN1L-05 39.00 0.5 2.5 PCN-1L PCN-1LE PCN-1LD PCN-1LZ (A)·(B)

XN2-3 14.33 3 2.2 PCN-2 PCN-2E PCN-6 PCN-2Z (A)·(B)PK-TEST

XN2-2 14.33 2 2.2 PCN-2 PCN-2E PCN-6 PCN-2Z (A)·(B)PK-SA PK-SB

XN2-2R (ruby ball) 14.33 2 2.2 PCN-2 PCN-2E PCN-6 PCN-2U PCN-6U PCN-2Z (A)·(B)PK-SAR PK-SBR

XN2-1 14.33 1 2.2 PCN-2 PCN-2E PCN-6 PCN-2Z (A)·(B)PK-TEST

XN2-08 14.33 0.8 2.2 PCN-2 PCN-2E PCN-6 PCN-2Z (A)·(B)PK-TEST

XN2-05 14.33 0.5 2.2 PCN-2 PCN-2E PCN-6 PCN-2Z (A)·(B)PK-TEST

XN2B-3 13.00 3 2.2 PCN-2B PCN-2BD PCN-7C PCN-SD

XN2B-2 13.00 2 2.2 PCN-2B PCN-2BD PCN-7C PCN-SD

XN2B-2R (ruby ball) 13.00 2 2.2 PCN-2B PCN-2BD PCN-7C PCN-SD PCN-2BU

XN2B-1 13.00 1 2.2 PCN-2B PCN-2BD PCN-7C PCN-SD

XN2B-08 13.00 0.8 2.2 PCN-2B PCN-2BD PCN-7C PCN-SD

XN2B-05 13.00 0.5 2.2 PCN-2B PCN-2BD PCN-7C PCN-SD

XNS-3 8.13 3 2.2 PCN-S

XNS-2 8.13 2 2.2 PCN-S

XNS-2R (ruby ball) 8.13 2 2.2 PCN-S PCN-SU

XNS-1 8.13 1 2.2 PCN-S

XNS-08 8.13 0.8 2.2 PCN-S

XNS-05 8.13 0.5 2.2 PCN-S

Part No. R(mm) φball (mm) φd(mm) Applicable Indicator

mm

φd

M 1.7×0.35

Gauge Anti-break

Measuring Element

Contact points with 2mm dia, super-hard are attached to all Pic-Test and New Pic-Test

indicators. S 3.0, 1.0mm, 0.8mm and 0.5mm dia, contact points are also stock items.

S 2.0 dia, Ruby ball is also available

第60页

Dimensions of Lever Type Dial Indicators

Contact Points Length and Types

59

2Resplaceable Contact Points (M1.7

×0.35)

Model L (mm)

PCN-5 . PCN-5U

PCN-6 . PCN-6U

21.3

17.94

Model L (mm)

PCN-1A . PCN-1AE . PCN-1AU . PCN-7A

PCN-1B . PCN-1BE . PCN-1BU . PCN-1BZ(A)(B)

PCN-1L . PCN-1LE . PCN-1LU . PCN-1LZ(A)(B)

PCN-2 . PCN-2E . PCN-2U . PCN-2Z(A)(B)

PCN-2B . PCN-2BU

PCN-S

PCN-7C

21.3

22.2

42.8

17.94

16.6

11.7

16.6

Model L (mm)

PC-1A . PC-1AE

PC-1B . PC-1BE

PC-1L . PC-1LE

PC-2

21.4

22.4

43.0

12.0

Model L (mm)

PC-1BW 22.4

Model L (mm)

PC-3

PC-4

PC-3L

21.4

12.0

43.0

Model L (mm)

PCN-0 21.3

Model L (mm)

PCN-1AD

PCN-2BD . PCN-SD

PCN-1LD

21.3

16.6

42.8

φ6-0.03

0

8

10 38.2 L

26

15.85 1.65

φ

7.85 35 40 16 12.54.5

φ6-0.03

7.6

10 44 L

23.5

12.8 1.6516

φ4535 133

0.4

6.2

0 φ35

10.3 L

29.9

21.4 16

27 10

φ

8 6

φ6-0.03 23.5 38.2 L

10

8

26.7

15.85 1.6530

7.85 40 φ46.5 (10.4) 4.5

0

φ6-0.03

7.6

10 44 L

9 12.8 9

φ35

0

φ6-0.03

10

8 L 38.2

26

15.85 1.65

φ29 4.5 40 16 12.5

7.85

0

φ6-0.03 16 37.5

φ35

L

3.5

7

10

17

0

第61页

60

2Precautions for Handling

Applied Examples

Precautions for Handling

● Dial gauges shall be used by being fixed to a rigid retainer to prevent the influence of flexure or the like.

In measurement, the measuring direction shall be made perpendicular to the center line of the measuring probe.

● In case they are not perpendicular, a correction by the following formula is necessary:

Due to various measuring direction, the contact point sometimes can not be angled perpendicular to the measuring

device.

Examples the diagrams below, where the measuring prove is set at an non-perpendicular angles and the distance

between the pivot of the contact point and the measuring device is signified by the letter H:

Displacement = quantity of pointer movement x COS θ

● When modification is not necessary:

If the measuring tolerance is 10% and the graph factor

is above 0.9, modification by calculation is unnecessary.

Example:

Using a PC-1A indicator, suppose the degree of angle is 30˚ and the

Pic Test reading is 0.05mm. The factor for the PC-1A indicator from

the graph is 0.87.

0.05mm x 0.87 = 0.0435 = 0.043mm

CylindersEccentricity Bores ThicknessTop SlidwaysSide Slideways

Measuring direction

Measuring direction

90˚

Measuring direction

Measuring direction

90˚

Measuring direction

Measuring direction

90˚

Measuring direction

Measuring direction

90˚

Measuring direction

Measuring direction

90˚

Measuring direction

Measuring direction

90˚

Measuring direction

Measuring direction

90˚

Measuring direction

Measuring direction

90˚

Measuring direction

Measuring direction

90˚

Measuring direction

Measuring direction

Measuring direction

90˚

Measuring direction

Measuring direction

90˚

Measuring direction

Measuring direction

90˚

Measuring direction

Measuring direction

90˚

Measuring direction

Measuring direction

90˚

Measuring direction

Measuring direction

90˚

Measuring direction

Measuring direction

H

H

H

Real measured value

Dial reading

θ

θ

θ

1.00

0.90

0.80

0.70

0.60

0.50

2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

0˚ 10˚ 20˚ 30˚ 40˚ 50˚ 60˚

H distance mm

PC-1A

PC-3

PCN-1A

PCN-0

PCN-5

1.00

0.90

0.80

0.70

0.60

0.50 factor factor

2 3 4 5 6 7 8 9 10 11

0˚ 10˚ 20˚ 30˚ 40˚ 50˚ 60˚

H distance

θ angle

mm

PC-2

PC-4

θ(angle

第62页

61

2 Lever type Dial Indicator

PK-TEST

Downward direction measurement

Model No. PK-SB (with dia. 2mm Carbide ball)

Model No. PK-SBR (with dia. 2mm Ruby ball)

Upward direction measurement

Model No. PK-SA (with dia. 2mm Carbide ball)

Model No. PK-SAR (with dia. 2mm Ruby ball)

Lever type Dial Indicator

World's first 0.001mm Graduation Lever type Indicator with Long Contact Point (14.18mm).

● It is possible to enable the longer contact point by New Mechanism.

(Utility Model Resistration No.3206149)

● Longer Contact Point can be reached your measurement work-piece.

● Contact Point is selectable "Carbide ball" or "Ruby ball".

Specifications

PK-SA Carbide

Upward PK-SAR Ruby 0.001 0.14 4.0 2.0 3.0 1.0

Dovetail Stem φ6mm

PK-SB Carbide

Downward (DS-6)

PK-SBR Ruby

Model Contact

Point

Direction of

Measurement

Graduation

(mm)

Range

(mm)

Wide-range forward

accuracy (µm)

10 scale indication

error (µm)

Hysteresis

(µm)

Repeatability

(µm) Accessory

Please purchase PK series after checking the direction of your measurement.

(PK series has no change Lever and no function to change direction automatically.)

New

第63页

with Carbide ball(Sφ2mm)

PK-SA・・・Upward direction

PK-SB・・・Downward direction

with Ruby ball(Sφ2mm)

PK-SAR・・・Upward direction

PK-SBR・・・Downward direction

Certificate of Inspection is attached.

We attach Certificate of Inspection at the time of inspection.

Attached Certificate of Inspection cannot be used as

Calibration Certificate.

Apply for Calibration Certificate when you Purchase

products.

Protect "Crystal" by Bezel made of Metal.

Bezel is made of Metal, it prevents "Crystal" from damage and

deformation.

Even if a scratch is generated on Crystal, it is easy to exchange

only "Crystal".

There is no aged deterioration on Bezel made of Metal and

even if using for a long time. it would be easy to turn Bezel and

adjust Zero setting smoothly.

Contact Point gets Longer.

Contact Point with groove of anti-break.

PK-TEST enables 6.05mm longer than

the conventional 0.001mm Graduation type.

When a force is applied to Contact Point, it is bent at

the groove to protect body and only exchange broken

Contact Point. (Apply to all our Pic Test Indicators)

Even if using for long hours, white color of Dial Plate

is comfort on the eyes.

Dial Plate based on

white color allows an

easy view of Pointer and

reducing fatigue of the

eyes.

Bezel

O-Ring

Crystal

Bent at the Groove

8.13mm

14.18mm

Current PCN

PK-TEST

Lever type Dial Indicator

62

2 PK-TEST Lever type Dial Indicator

第64页

Crystal is formed by press-molding special acrylic plate.

Hold by Dovetail Stem.

Prevent looseness by 3 points screws.

Lever supporting point is used with

Pivot bearing with both left and right

side

Mechanism with easy maintenance

even using for a long time.

Special acrylic plate is superior to injection molding material in "Oil-proof",

"Chemical resistance" and "Transparency" and it is formed by a press work as

convex R shape.

Dovetail Stem can be hold by 3 positions dovetail groove.

(Upper, Lower and Back side positions.)

There are 3 kinds of diameter 6 and 8mm. (PK series is including

6mm as standard but you can choose 4 or 8mm.)

In PK series, adapt new body

and base metal for 3 points

fixing screws from 2 points

fixing screws,which more

strengthens the fixing force.

Unique structure using Pivot bearing used with both

side of left and right is high reliable and keeps high

repeatability even if using for a long time.

(Apply to all Pic Test indicators)

It is possible to repair by the same movement method

of a clock and keeping durability of bearing due to

Jewel.

(Apply to all Pic Test Indicators)

DS-8 :φ8mm

DS-6 :φ6mm

DS-4 :φ4mm

Pivot bearing

Left side

Pivot bearing

Right side

Jewel Bearings

Pocket Type

Mechanism

3 positions dovetail groove.

New adapted fixed screw

63

2Lever type Dial Indicator

第65页

Dimensions

Upward Measurement

Replaceable Contact Points

Mounting Position of

Dovetail Stem

Dovetail Stem

Downward Measurement

DS-8

Stem dia. 8mm

DS-6

Stem dia. 6mm

XN2-2R

(Ruby ball dia. 2mm)

Standard for

PK-SAR & PK-SBR

XN2-2

(Carbide ball dia. 2mm)

Standard for

PK-SA & PK-SB

XN2-05

(Carbide ball dia. 0.5mm)

XN2-08

(Carbide ball dia. 0.8mm)

XN2-1

(Carbide ball dia. 1.0mm)

XN2-3

(Carbide ball dia. 3mm)

DS-4

Stem dia. 4mm

3 positions for dovetail Stem

Contact Point (Carbide)

for PK-SA

for PK-SB

PK-SA

PK-SAR

Contact Point (Ruby)

for PK-SAR

for PK-SBR

PK-SB

PK-SBR

Standard Accessory : DS-6

Option : DS-4 and DS-8

XN2-2

XN2-2R

Lever type Dial Indicator

64

2 PK-TEST Lever type Dial Indicator

第66页

65

・Standard Cylinder Gauges

CC Series

CG Series

・Special Cylinder Gauges

S Series

・"R" Series

Cylinder Gauges 3

3

SECTION

第67页

Standard Cylinder Gauges

66

3 CCseries

Peacock offers a complete line of Dial Bore Gauges with interchangeable anvils and necessary accessories to perform close tolerance measurements of holes, taper and roundness.

● Dial gauge mounting knob is very simple of and sure avoiding demerit of collet-system.

● The contact point is tungsten carbide ball.

● The standard ball tipped at the replacement rod is made of steel.

The sintered hard-alloy ball is also available to tip.

● Wide range accuracy………5μm or less

Adjacent error………………2μm or less

Repeated accuracy…………2μm or less

● Effective measuring range is 0.5 mm (CC-02 CC-01)

● Effective measuring range is 1.2 mm (CC-1 to CC-6)

Standard Cylinder Gauges

Model Range (mm) Length below grip

(mm)

Number of Feelers

(mm)

Thickness of

Washers

(mm)

CC-02

CC-01

CC-1

CC-2

CC-3

CC-3C

CC-4

CC-5

CC-6

6 ~ 10

10 ~ 18

18 ~ 35

35 ~ 60

50 ~100

50 ~150

100~160

160~250

250~400

50

100

150

150

150

150

250

250

400

Intervals 0.5 mm x 9

Intervals 1 mm x 9

Intervals 2 mm x 9

Intervals 5 mm x 6

Intervals 5 mm x 11

Intervals 5 mm x 11

Intervals 10 mm x 7

Intervals 10 mm x 10

Intervals 10 mm x 16

──

0.5 mm

0.5, 1 mm each

1,2,3 mm each

1,2,3 mm each

1,2,3 mm each

1,2,3,4 mm each

1,2,3,4 mm each

1,2,3,4 mm each

● List of special length below grip (available on request)

CC-01

CC-1

CC-2

CC-3

CC-3C

CC-4

CC-5

CC-6

CC-1S

CC-2S

CC-3S

CC-3CS

standard -

standard

- -

L=50

(mm)

L=100

(mm)

L=200

(mm)

L=300

(mm)

L=400

(mm)

L=500

(mm)

L=600

(mm)

L=700

(mm)

L=800

(mm)

L=900

(mm)

L=1000

(mm)

L=1500

(mm)

L=2000

(mm)

CC-2 complete set

Length below grip (L)

CC-2 head details

JIS B 7515

Range: 50~150mm

CC-3C

Range: 100~160mm

CC-4

Range: 250~400mm

CC-6

● With 50 mm extension

collar

More than L=600mm for CC-2 can not measure from 35 to 44mm and can measure from 45 to 60mm ID.

Specifications

CC-02

Range: 6~10mm

Range: 10~18mm

CC-01

※Dial gauge is not furnished and supplied only on request. Suitable dial gauges are 17Z, 57B (0.01mm) and 15Z, 5F

(0.001mm).

第68页

67

3 Short Size Cylinder Gauges

S series

This is a compact cylinder gauge with a length below grip of 50 mm.

It is used when a standard item is too long to measure the object or a shorter length of below grip is required for

conveniently.

Specifications are same as standard model.

Short Size Cylinder Gauges

Range: 35~60mm

CC-2S

Range: 18~35mm

CC-1S

Range: 50~150mm

CC-3CS

● With 50 mm

extension collar

Dimension

Outer Dimension

249 150 5.75 70 23 20 10 18~35 13 11.5

251.5 150 8.5 70 23 20 10 35~60 22 17

253 150 9 70 23 20 10 50~100 30 18

253 150 9 70 23 20 10 50~150 30 18

370 250 12 85 23 25 13 100~160 50 24

391.5 251.5 14 100 26 25 16 160~250 70 28

540 400 14 100 26 25 16 250~400 100 28

150 50 5.75 70 23 20 10 18~35 13 11.5

151.5 50 8.5 70 23 20 10 35~60 22 17

152 50 9 70 23 20 10 50~100 30 18

152 50 9 70 23 20 10 50~150 30 18

CC-1

CC-2

CC-3

CC-3C

CC-4

CC-5

CC-6

CC-1S

CC-2S

CC-3S

CC-3CS

Model A B C D E F G H I J

D

A

B(length below grip) C

H I

J

E

φ

φ

G

F

第69页

Cylinder Gauges (Blind Hole Type)

68

3 CGseries

If using a CC type cylinder gauge for blind hole bore diameter, its guide plate interrupt the measurement at a point

deeper than "T", as shown in the figure below.

In such case, the CG type with modified guide plate is suitable for measurement of the diameter to the point as deep as "t".

● Wide range accuracy…5μm or less

Adjacent error…………2μm or less

Repeated accuracy……2μm or less

● Effective measuring range is 0.5 mm (CG-01)

● Effective measuring range is 1.2 mm (CG-1 to CG-6)

Cylinder Gauges (Blind Hole Type)

CG-3 head details

CG-01

CG-1

CG-2

CG-3

CG-3C

CG-4

CG-5

CG-6

10 ~ 18

18 ~ 35

35 ~ 60

50 ~100

50 ~150

100~160

160~250

250~400

100

150

150

150

150

250

250

400

Intervals 1 mm x 9

Intervals 2 mm x 9

Intervals 5 mm x 6

Intervals 5 mm x 11

Intervals 5 mm x 11

Intervals 10 mm x 7

Intervals 10 mm x 10

Intervals 10 mm x 16

0.5 mm each

0.5, 1 mm each

0.5,1,2,3 mm each

0.5,1,2,3 mm each

0.5,1,2,3 mm each

1,2,3,4 mm each

1,2,3,4 mm each

1,2,3,4 mm each

● List of special length below grip (available on request)

CG-01

CG-1

CG-2

CG-3

CG-3C

CG-4

CG-5

CG-6

standard

standard

standard

standard

standard

standard

standard

standard

L=50

(mm)

L=100

(mm)

L=150

(mm)

L=200

(mm)

L=250

(mm)

L=300

(mm)

L=400

(mm)

L=500

(mm)

L=600

(mm)

L=700

(mm)

L=800

(mm)

L=900

(mm)

L=1000

(mm)

3.0mm

(4.5mm for CG-6)

Range: 18~35mm

CG-1

Range: 50~100mm

CG-3

Range: 100~160mm

CG-4

※ Dial gauge is not furnished and supplied only on request. Suitable dial gauges are 17Z, 57B (0.01mm) and 15Z, 5F (0.001mm).

※ CG-3C includes 50 mm extension collar.

※ In general, it is the range from the origin, that is the position where the plunger is pushed in by 0.1 mm, to the position where the plunger is pushed in further by 1.2 mm.

Specifications

Model Range (mm) Length below grip

(mm)

Number of Feelers

(mm)

Thickness of

Washers

(mm)

3mm

Range: 10~18mm

CG-01

● Blind hole type

   CC    CG

Applied Example

CG-01:Measuring depth is 5mm

in case of measuring from 10 to

11mm. From 12 to 18mm, the

measuring depth is 3mm.

第70页

CC-4

Feeler

Dimensions for Feeler and Washer for Cylinder Gauges

CC-6

Feeler

CC-5

Feeler

CC-1 Feeler CC-2 Feeler CC-3・3C Feeler

CC-4 Feeler CC-5 Feeler CC-6 Feeler

CC-1~6 Washer

M4×0.5

φ5

5/32"Steel

L 23.2 3.2

φ7 SR5

5/32"Steel

7.5

φ5φ5φ8

L

5/32"Steel

7.5 L

φ5φ8φ5

φAφB

T

※ Only 18mm is SR5

3/16"Steel

φ6

15 L

φ11

φ7

3/16"Steel

φ6

15 L

φ11

φ7

1/4"Steel

φ9

φ13

φ9

15 L

※18 2

20 4

22 6

24 8

26 10

28 12

30 14

32 16

34 18

CC-1

Feeler

160 10

170 20

180 30

190 40

200 50

210 60

220 70

230 80

240 90

250 100

Model T(mm) A(mm) B(mm)

0.5, 1 4.1 7

1, 2, 3 5.1 8

1, 2, 3 5.1 8

1, 2, 3, 4 6.1 10

1, 2, 3, 4 6.1 10

1, 2, 3, 4 9.1 13

CC-1

CC-2

CC-3・3C

CC-4

CC-5

CC-6

250 10

260 20

270 30

280 40

290 50

300 60

310 70

320 80

330 90

340 100

350 110

360 120

370 130

380 140

390 150

400 160

35 5

40 10

45 15

50 20

55 25

60 30

100 10

110 20

120 30

130 40

140 50

150 60

160 70

Model Size L(mm) (mm) Model Size L(mm) (mm) Model Size L(mm) (mm)

Model Size L(mm) (mm) Model Size L(mm) (mm) Model Size L(mm) (mm)

50 5

55 10

60 15

65 20

70 25

75 30

80 35

85 40

90 45

95 50

100 55

CC-3・3C

Feeler

CC-2

Feeler

69

3Dimensions for Feeler and Washer for Cylinder Gauges

第71页

Extension collar

Cylinder Gauges

70

3Cylinder Gauges

Do you have any trouble when measuring internal diameter?

If so,we offer more radii of Contact Point & Feeler for Cylinder Gauges "R" Series.

● Wide range accuracy…5μm or less

Adjacent error…………2μm or less

Repeated accuracy……2μm or less

Model Range Length below grip Number of feelers Thickness of washers

CG-01R

CG-1R

CG-2R

CG-3R

CG-3CR

10~ 18mm

18~ 35mm

35~ 60mm

50~100mm

50~150mm

100mm

150mm

150mm

150mm

150mm

0.5mm

0.5, 1mm each

0.5, 1, 2, 3mm each

0.5, 1, 2, 3mm each

0.5, 1, 2, 3mm each

------

------

------

------

50mm

Intervals 0.5mm× 9

Intervals 2mm× 9

Intervals 5mm× 6

Intervals 5mm×11

Intervals 5mm×11

Specifications for CG-"R" series

Model Range Length below grip Number of feelers Thickness of washers Extension collar

CC-01R

CC-1R

CC-2R

CC-3R

CC-3CR

10~ 18mm

18~ 35mm

35~ 60mm

50~100mm

50~150mm

100mm

150mm

150mm

150mm

150mm

0.5mm

0.5, 1mm each

1, 2, 3mm each

1, 2, 3mm each

1, 2, 3mm each

------

------

------

------

50mm

Intervals 0.5mm× 9

Intervals 2mm× 9

Intervals 5mm× 6

Intervals 5mm×11

Intervals 5mm×11

Specifications for CC-"R" series

CC-1R CC-3R

CC•CG-Rseries

Note: CG-01, in case 10~11mm measurement, the measuring depth is 5mm but 11~18mm is 3mm measuring depth.

第72页

71

3Cylinder Gauges

CC-01R

CG-01R

CC-1R・CG-1R・CG-2R

CG-3R・CG-3CR

CC-2R・CC-3R

CC-3CR

Contact Point Hv700±50 (Tip heat treatment and hardened)

CC-01R

CG-01R

CC-1R CC-2R・CC-3R

CC-3CR

Feeler Hv700±50 (Tip heat treatment and hardened)

CG-1R CG-2R・CG-3R

CG-3CR

Feeler Hv700±50 (Tip heat treatment and hardened) 1 Long Size of Length below grip

Cylinder Gauge

2 Short Size of Length below grip

Cylinder Gauge

3 Short Size of the overall length

Cylinder Ggauge

4 L-shaped Cylinder Gauge

"R" Series Cylinder Gauges

can be made Special

Production as following:

3 4

第73页

72

3Cylinder Gauges

Dimensions for Feeler and Washer for R series Cylinder Gauges:

CC-01R Feeler

CC-1R Feeler

CC-2R Feeler

CC-3R・CC-3CR Feeler

CG-01R Feeler

CG-1R Feeler

CG-2R Feeler

CG-3R・CG-3CR Feeler

R type Washer

Size 10mm Size 11~18mm

Size 10mm Size 11~18mm

Size 18mm Size 20~34mm

Size 18mm Size 20~34mm

Size (mm) L (mm)

50

55

60

65

70

75

5

10

15

20

25

30

Size (mm) L (mm)

80

85

90

95

100

35

40

45

50

55

Model T A B

0.5

0.5・1

1・2・3

1・2・3

0.5

0.5・1

0.5・1・2・3

0.5・1・2・3

3.1

4.1

5.1

5.1

3.1

4.1

4.1

4.1

4.5

7

8

8

4.5

5

6

6

CC01-R

CC-1R

CC-2R

CC-3R・CC-3CR

CG01-R

CG-1R

CG-2R

CG-3R・CG-3CR

Size (mm) L (mm)

50

55

60

65

70

75

5

10

15

20

25

30

Size (mm) L (mm)

80

85

90

95

100

35

40

45

50

55

Size (mm) L (mm)

35

40

45

5

10

15

Size (mm) L (mm)

50

55

60

20

25

30

Size (mm) L (mm)

10

11

12

13

14

1.5

2.5

3.5

4.5

5.5

Size (mm) L (mm)

15

16

17

18

6.5

7.5

8.5

9.5

Size (mm) L (mm)

10

11

12

13

14

1.5

2.5

3.5

4.5

5.5

Size (mm) L (mm)

15

16

17

18

6.5

7.5

8.5

9.5

Size (mm) L (mm)

18

20

22

24

26

2

4

6

8

10

Size (mm) L (mm)

28

30

32

34

12

14

16

18

Size (mm) L (mm)

35

40

45

5

10

15

Size (mm) L (mm)

50

55

60

20

25

30

Size (mm) L (mm)

18

20

22

24

26

2

4

6

8

10

Size (mm) L (mm)

28

30

32

34

12

14

16

18

第74页

73

・Dial Gages

・Dial Gages (Metric)

・Pic Test Indicators

・Dial Bore Gage Sets

・Dial Thickness Gage

Inch Scale Dial Indicators

4

SECTION

4

第75页

Dial Gages

74

4 0.001” Inch Scale Dial Indicators

Dimensions

● Easy-reading distinct graduations.

● Inch models have standard black needles and white dial faces or new high visibility orange needles and black faces.

Metric models have yellow dial faces. (see page 76)

● Hard, satin-chrome finish.

● Superior quality of spindle rack, pinions and gear trains ensure longevity.

● Meets or exceeds applicable US federal specifications.

● Conforms to AGD specifications.

C

13/32”

1/4”DIA

1/4”

1/4”

3/4”

3/8”DIA

B

A

TRAVEL 4-48NF

THREAD

A B C

AGD 1 1-37/64” 1-5/8” 11/16”

AGD 2 2-3/64” 2” 25/32”

Graduation: 0.001”

Range: 0.2”

1200

Graduation: 0.001”

Range: 1.0”

1330

Graduation: 0.001”

Range: 1.0”

1330B

Graduation: 0.001”

Range: 0.50”

1310B

Graduation: 0.001”

Range: 0.50”

1310

● Lug back

● Lug back ● Lug back ● Lug back ● Lug back

第76页

75

0.001” 4

0.0001”

Inch Scale Dial Indicators

Graduation: 0.001”

Range: 2.0”

1364

Graduation: 0.0001”

Range: 0.05”

1460B

Graduation: 0.0001”

Range: 0.05”

1460

Graduation: 0.0001”

Range: 0.05”

1440B

Graduation: 0.0001”

Range: 0.05”

1440

Graduation: 0.001”

Range: 2.0”

1364B

1200

1330

1310

1364

1440

1460

-----

1330B

1310B

1364B

1440B

1460B

Lug

Lug

Lug

Lug

Lug

Flat

.20"

1.0"

.50"

2.0"

.05"

.05"

.0008"

.002"

.001"

.004"

.0003"

.0003"

.0003"

.0004"

.0003"

.0004"

.0002"

.0002"

1.4N

2.0N

1.8N

2.5N

1.5N

1.5N

.001"

.001"

.001"

.001"

.0001"

.0001"

±0-50-100

±0-50-100

±0-50-100

±0-50-100

±0-5-10

0-5-0

1

2

2

2

2

2

Specifications

White face

Model No.

Black face

Model No.

Measuring

range Graduation

Wide range

forward

accuracy

Retrace error Measuring force

(less than) AGD Back

Config. Reading

● Lug back ● Lug back

● Lug back ● Lug back ● Flat back ● Flat back

第77页

76

4 Metric Graduations 0.01mm Metric Graduations 0.01mm

Graduation: 0.01mm

Range: 50.0mm

1361

Graduation: 0.01mm

Range: 20.0mm

1331

Graduation: 0.01mm

Range: 10.0mm

1311

Graduation: 0.01mm

Range: 2.0mm

1201

Specifications

● Lug back ● Lug back ● Lug back ● Lug back

1201

1311

1331

1361

Lug

Lug

Lug

Lug

4.0mm

10.0mm

20.0mm

50.0mm

12μm

15μm

25μm

50μm

3μm

3μm

4μm

5μm

1.4N

1.4N

2.2N

2.5N

0.01mm

0.01mm

0.01mm

0.01mm

±0-50-100

±0-50-100

±0-50-100

±0-50-100

1

2

2

2

Model No. Measuring

range Graduation

Wide range

forward

accuracy

Retrace error Measuring force

(less than) AGD Back

Config. Reading

Dimensions

C

13/32”

1/4”DIA

1/4”

1/4”

3/4”

3/8”DIA

B

A

TRAVEL 4-48NF

THREAD

A B C

AGD 1 1-37/64” 1-5/8” 11/16”

AGD 2 2-3/64” 2” 25/32”

第78页

Clamping bar, wrench

77

4

Pic Test Indicators

Inch Scale Pic Test Indicators

● Auto-reversing.

● Comes complete with .038”, .078”, .125” dia hardchromed contact points, Clamping bars, wrench and three

stems: 3/8”, 1/4” and 5/32”.

● 180°swing on point and shaft.

● Fully jeweled movements.

● White face models have black needles, numbers and

graduations. Black face models have bright,

flourescent orange needles with white numbers and

graduations.

● Dial diameter is 1-3/8”.

● Universal positioning capability.

● Dovetoils on top, back & front.

● Excellent rigid

● Non-magnetic

Horizontal Type

Graduation: 0.0001”

Range: 0.008”

2010B

Graduation: 0.0001”

Range: 0.008”

2010

Graduation: 0.0005”

Range: 0.030”

2000B

Graduation: 0.0005”

Range: 0.040”

2030B

Graduation: 0.0005”

Range: 0.030”

2000

Graduation: 0.0005”

Range: 0.040”

2030

Specifications

Set Configurations

Contact points

Stems

φ0.038” φ0.078” φ0.118”

3/8” 1/4” 5/32”

2000

2010

2030

2000B

2010B

2030B

0-15-0

0-4-0

0-20-0

.0005"

.0003"

.0010"

.0003"

.0002"

.0003"

.030"

.008"

.040"

.0005"

.0001"

.0005"

.750"

.375"

1.750"

0.3N

0.3N

0.3N

White face

Model No.

Black face

Model No.

Measuring

range Reading

Wide range

forward

accuracy

Backward error Contact point

length

Measuring force

(less than) Graduation

第79页

78

4Inch Scale Pic Test Indicators

Vertical Type

Large Size Dial Face Type

Graduation: 0.0001”

Range: 0.008”

2060B

Graduation: 0.0001”

Range: 0.008”

2210B

Graduation: 0.0001”

Range: 0.008”

2210

Graduation: 0.0005”

Range: 0.030”

2200B

Graduation: 0.0005”

Range: 0.030”

2200

Graduation: 0.0001”

Range: 0.008”

2060

Graduation: 0.0005”

Range: 0.030”

2050B

Graduation: 0.0005”

Range: 0.030”

2050

The dial plate size of 2200, 2200B, 2210, and 2210B models has been enlarged, with easy reading due to the

lager scale spacing, as a result.

Specifications

2050

2060

2200

2210

2050B

2060B

2200B

2210B

0-15-0

0-4-0

0-15-0

0-4-0

.0005"

.0003"

.0005"

.0003"

.0003"

.0002"

.0003"

.0002"

.030"

.008"

.030"

.008"

.0005"

.0001"

.0005"

.0001"

.750"

.375"

.750"

.375"

0.3N

0.3N

0.3N

0.3N

White face

Model No.

Black face

Model No.

Measuring

range Reading

Wide range

forward

accuracy

Backward error Contact point

length

Measuring force

(less than) Graduation

Set Configurations

1-53/64"

Large Size Dial Face

Clamping bar, wrench

Contact points

Stems

φ0.038” φ0.078” φ0.118”

3/8” 1/4” 5/32”

第80页

79

4 Dial Bore Gage Sets Inch Scale Dial Bore Gage Sets

● Each set includes a high quality ADG2 Dial indicator with .0001” graduations.

High precision, combined with ultra smooth movement, makes this the set for the most demanding users.

● Set comes complete with protective cover and fitted case.

● For close tolerance measurements of hole sizes, ID taper dimensions and roundness.

● Each set includes a reference chart, clearly specifying Spacer and Feeler sizes, for each measurement range.

Specifications

Range: 0.25-0.4”

5710

Range: 0.75-1.50”

5740

Range: 6.0-10.0”

5790B

Range: 0.37-0.75”

5730B

5710

5730

5740

5750

5770

5790

5710B

5730B

5740B

5750B

5770B

5790B

.00008"

.00008"

.00008"

.00008"

.00008"

.00008"

.00008"

.00008"

.00008"

.00008"

.00008"

.00008"

1-31/32"

3-15/16"

5-29/32"

5-29/32"

5-29/32"

9-29/32"

.250-.400"

.370-.750"

.750-1.50"

1.50-2.50"

2.00-6.00"

6.00-10.0"

.0002"

.0002"

.0002"

.0002"

.0002"

.0002"

-----

1

2

2

2

4

8

10

8

6

11

9

White face

Model No.

Black face

Model No. Range Adjacent error Repeated

error

Length below

Grip

Number of

Spacer

Number of

Feeler

Wide range

accuracy

5730 complete set

第81页

Dial Thickness Gage

80

4

● Designed for quick and accurate measurement of small parts, sheet metal, paper, fabric, etc.

● Convenient, one-handed operation.

● Preloaded spindle for consistent measuring pressure.

● Adjustable zero setting with bezel.

● Baked enamel finish.

● Distinct, fine graduations for easy reading.

● Spindle made of hardened steel.

Inch Scale Dial Thickness Gages

Graduation: 0.001”

Range: 0.5”

4600

Specifications

4600 .50" .001" .78" .0010" 1.8N

Model No Range Graduation Accuracy Measuring force

(less than) Throat depth

● For measuring thickness of paper

第82页

81

・NB

・CCT-2

Gauge Testers

5

5

SECTION

第83页

82

5Gauge Tester

Dial Gauge Tester Model NB

● This is a calibration tester having a high precision micrometer with the minimum scale of 1μm.

It can be used in order to calibrate dial gauges as well as other displacement gauges.

● The stancion is vertically adjustable according to the type of gauges and reading is done while looking at the scale

plate and the cursor line.

158

(235.5)

Gauge fixing screw

Gauge supporting frame

Base

Main

pillar

Graduation disk

Magnifying mirror

with reference line

Micrometer head

● Lever-type dial gauge ● Back plunger type dial gauge Component Names

Specifications

NB 0.001(1μm) 20 under ±1 0.5/rev. Carbide chip 8mm dia. 10mm dia.

Graduation (mm) Measurement Range (mm)

Micrometer head Forward Accuracy

(µm)

Feed per revolution

(mm) Spindle tip Gauge fixing

dimension

(mm)

Model

Gauge Tester

( Dial Indicator Testing Equipment )

第84页

φ6~10mm

φ10~18mm

φ18~35mm

φ35~60mm

φ50~100mm

φ100~160mm

φ160~250mm

φ250~400mm

83

5Gauge Tester

Cylinder Gauge Tester Model CCT-2

● This is a calibration tester used exclusively for cylinder gauges having a high precision micrometer with the

minimum scale of 1μm.

● An outer cylinder is held erectly so that deflection may not affect the measurements and a center rod for pressing is

provided on the moving bed in order to prevent from errors due to the difference of measuring force.

●Inspection of dial gauges is also possible.

450

350

Center clamp

Column

Center

Height adjustment stand

Cursor lens

Graduation board

Micrometer

Stand jam

Adjustable stand B Adjustable

stand A

Base

Component Names

CCT-2 0.001 20 under ±1 0.5/rev. Carbide chip

Cylinder gauges to be possibly inspected

● All the cylinder gauges of JIS B 7515 Standards

● All the CC and CG models of "PEACOCK"

Specifications

Graduation (mm) Measurement Range (mm)

Micrometer head Forward Accuracy

(µm)

Feed per revolution

(mm) Model Spindle tip

Gauge Tester

( Cylinder Gauge Testing Equipment )

第85页

84

MEMO

第86页

85

・Dial Thickness Gauges

(0.01mm, 0.001mm)

・Dial Swift Gauge

・Paper Thickness Gauge

・Dial Thickness Gauges (Large Type)

(0.01mm, 0.05mm)

・Dial Thickness Gauge (Roller Type)

・Dial Sheet Gauges

(0.01mm, 0.05mm)

・Dial Pipe Gauges

・Dial Lens Gauge

・Dial Upright Gauges

・Constant Pressure Thickness Gauge

Thickness Gauges

6

6

SECTION

第87页

0~10mm

0~10mm

0~10mm

Dial Thickness Gauges

86

6 0.01mm type

These thickness gauges are especially handy for measuring thickness of small

parts, metal, rubber, vinyl, paper, foil and other sheet material.

● The objects to be measured is clamped by simple lever operation.

The measured values are read directly on the dial gauge.

● Since the anvil and the contact point are adjusted for parallelism, accurate measured values

are obtained.

Dial Thickness Gauges

Graduation: 0.01mm

Range: 0~10mm

● φ10mm flat contact point

and anvil (Ceramic)

G

Graduation: 0.01mm

Range: 0~10mm

● Measuring force initial

pressure 0.4N

G-0.4N

Graduation: 0.01mm

Range: 0~10mm

● φ20mm flat contact point

and anvil (Metal)

G-20

Graduation: 0.01mm

Range: 0~10mm

● Measuring force final

pressure 2.4N

G-2.4N

Graduation: 0.01mm

Range: 0~10mm

● φ30mm flat contact point

and anvil (Metal)

G-30

New

New

Graduation: 0.01mm

Range: 0~10mm

● φ5mm flat contact point

and anvil (Metal)

G-1A

Graduation: 0.01mm

Range: 0~10mm

● φ6mm flat contact point

and anvil (Ceramic)

● The frame on the

anvil side is cut,

which to be flush

contact point,

anvil and frame.

G-1M

New

New

Graduation: 0.01mm

Range: 0~20mm

● φ10mm flat contact point

and anvil (Ceramic)

G-2

Graduation: 0.01mm

Range: 30mm

● φ10mm flat contact point

and anvil (Ceramic)

● Anvil side is adjustable

● More than 10mm range is

comparative measurement.

G-3

Graduation: 0.01mm

Range: 65mm

● Spherical contact point

● Anvil side is adjustable

● More than 10mm range is

comparative measurement.

G-4

50

80

5

70 0

60 4

1

2

3

6

7

8

9

40

90 10

0

20

30

0.01mm

φ4

49.5

30

2-SR4

74.5 17 33.5 29

10

65

第88页

87

6Dial Thickness Gauge

Specifications

G

G-0.4N

G-2.4N

G-MT

G-1A

G-1M

G-2

G-3

G-4

G-20

G-30

H

H-0.4N

H-2.4N

H-MT

H-1A

H-2

H-3

H-20

H-30

0.01

0.01

0.01

0.01

0.01

0.01

0.01

0.01

0.01

0.01

0.01

0.01

0.01

0.01

0.01

0.01

0.01

0.01

0.01

0.01

20

20

20

20

20

20

33

20

30

20

20

120

120

120

120

120

170

170

120

120

0~10

0~10

0~10

0~10

0~10

0~10

0~20

30

65

0~10

0~10

0~10

0~10

0~10

0~10

0~10

0~10

0~10

0~10

0~10

±20

±20

±20

±20

±20

±20

±22

±20

±20

±20

±20

±20

±20

±20

±20

±20

±20

±20

±20

±20

10

10

10

10(Metal)

5

6

10

10

Spherical

20(Metal)

30(Metal)

10

10

10

10(Metal)

5

Ball type

Ball type

20(Metal)

30(Metal)

5

5

5

5

5

5

5

5

15

20

5

5

5

5

5

15

20

1.8

Initial pressure 0.4N

Final pressure 2.4N

1.8

1.8

1.8

2.0

1.8

1.8

1.8

1.8

1.8

Initial pressure 0.4N

Final pressure 2.4N

1.8

1.8

1.8

1.8

1.8

1.8

Model Graduation

(mm)

Throat depth

(mm)

Range

(mm)

Accuracy

(µm)

Measuring force

less than(N)

Contact Point

Dia (mm) Parallelism (µm)

170mm

Graduation: 0.01mm

Range: 0~10mm

● Ball type contact point and anvil

H-2

Graduation: 0.01mm

Range: 0~10mm

● Ball type contact point and roller type anvil

H-3

● Bottle Wall Thickness Gauge ● Bottle Wall Thickness Gauge

(Roller type anvil)

Graduation: 0.01mm

Range: 0~10mm

H-20

● φ20mm flat contact point and anvil (Metal)

Graduation: 0.01mm

Range: 0~10mm

H-30

● φ30mm flat contact point and anvil (Metal)

Graduation: 0.01mm

Range: 0~10mm

H-1A

● φ5mm flat contact point and anvil (Metal)

New

New

0~10mm

Graduation: 0.01mm

Range: 0~10mm

H

● φ10mm flat contact point and anvil (Ceramic)

Graduation: 0.01mm

Range: 0~10mm

H-0.4N

● Measuring force inital pressure 0.4N

Graduation: 0.01mm

Range: 0~10mm

H-2.4N

● Measuring force final pressure 2.4N

New

New

※ G-3/G-4 : Measuring range of dial gauge is 10mm.

第89页

Dial Thickness Gauges

88

6 0.001mm type PAT. No. 3052674

Dial Swift Gauge

The dial swift gauge is used for the same pur- pose as an ordinary micrometer to measure outside sizes.

● The spindle is always pulled upward by the force of

the spring. The knob at the top of the gauge is pushed

down by finger to clamp an object in measurement.

● It will show its power for measurement of thickness,

heights and diameters.

Dial Thickness Gauges Dial Swift Gauge /

Model Graduation (mm) Range (mm) Throat depth (mm) Accuracy (µm)

Contact Point

Dia (mm) Parallelism (µm)

Specifications

Q-1 0.05 0~25 30 ±100 5.5 10

Graduation: 0.05mm

Range: 0~25mm

Q-1

● New thinkness gauges with 0.001mm graduations.

● Newly developed special frame minimizes inspecting errors resulting from thermal changes. Zero reference point

will remain accurate even after many hours of use or extreme swings in temperature.

G-6C

G-7C

0.001

0.001

±5

±10

0~1

0~5

20

20

5

5

3

3

1.8

1.8

Specifications

Graduation: 0.001mm

Range: 0~1mm

G-6C

Graduation: 0.001mm

Range: 0~5mm

G-7C

Model Graduation

(mm)

Throat depth

(mm)

Range

(mm)

Accuracy

(µm)

Measuring force

less than (N)

Contact Point

Dia (mm) Parallelism (µm)

● φ5mm flat contact point and

anvil

(Metal)

● φ5mm flat contact point and

anvil

(Metal)

第90页

89

6Paper Thickness Gauge

Paper Thickness Gauge

●μm unit on the dial Plate suitable for paper thickness measurement.

Graduation: 0.01mm

Range: 0〜10mm

PG-10

Bezel

Lever

Cap

Pointer

Spindle

Contact Point

(Contact Point Set)

Anvil

Inner Dial

Crystal

Hand

Frame

Outer Dial

How to adjust setting 0 of Pointer. ● Normally, Pointer and Hand without inserting a

work-piece point to 0. There is a possibility the

Pointer is not on 0 position due to temperature

fluctuation. In this case, set Pointer to 0 by

rotating the Bezel.

● Throat Depth 20mm

● Accuracy ±20μm

● Contact Point dia. 10mm

● Parallelism 5μm

● Measuring force less than 1.8N

Name of each Parts

第91页

Dial Thickness Gauges (Large type)

90

6Dial Thickness Gauge (Large type) (Roller type) /

J-A

J-B

0.01

0.05

0~20

0~35

150

140

±22

±100

10

20

5

25

2.0

3.0

These large thickness gauges having extended throat depth to measure at the center of wide sheets.

Graduation: 0.01mm

Range: 0~20mm

● The gauge sits by stand

● φ10mm flat contact

point andφ20mm anvil

(Metal)

J-A

Graduation: 0.05mm

Range: 0~35mm

● φ20mm flat contact point

and anvil (Metal)

J-B

φD

Specifications

Model Graduation

(mm)

Throat depth

(mm)

Range

(mm)

Accuracy

(µm)

Measuring force

less than (N)

Contact Point

Dia (mm) Parallelism (µm)

Dial Thickness Gauge Roller type

HR-1 0.01 0~15 70 ±22 22 7 10 2.0

Specifications

Special gauges for measuring

of horizontally sliding a gauge

with an object to be in inspected

laid since the contact point and

anvil are made with the roller.

Convenient to continuously measuring thickness of thin objects,

paper, rubber and film etc.

T

(0~15mm)

Throat depth

(mm) Model Graduation

(mm)

Range

(mm)

Accuracy

(µm) OD (mm) Width (mm)

Roller contact points

Parallelism

(µm)

Measuring force

less than

(N)

HR-1

Custom order available

Optional φ30,40 and 50mm contact points and

anvils are available.

Please specify material for contact point and anvil,

either Metal (SK) material or aluminum (AL).

第92页

91

6 Dial Sheet Gauges

0.01mm and 0.05mm

Dial Sheet Gauges

● The sheet gauges can measure wide sheets since the throat depth of this gauges having 300, 500 and 690mm.

Graduation: 0.01mm

Range: 0~20mm

K-1

Graduation: 0.05mm

Range: 0~35mm

K-2

Graduation: 0.01mm

Range: 0~20mm

K-3

Graduation: 0.05mm

Range: 0~50mm

K-4

φD

Custom order available

Specifications

Examples

K-1

K-2

K-3

K-4

0.01

0.05

0.01

0.05

±22

±100

±22

±100

0~20

0~35

0~20

0~50

300

300

500

500

10

20

10

25

10

25

10

25

2.0

3.0

3.0

3.0

Model Graduation

(mm)

Throat depth

(mm)

Range

(mm)

Accuracy

(µm)

Measuring force

less than

(N)

Contact Point

Dia (mm) Parallelism (µm)

● φ10mm flat contact point and

φ20mm anvil (Metal)

● φ10mm flat contact point and

φ20mm anvil (Metal)

● φ25mm flat contact point and

anvil (Metal)

● φ20mm flat contact point and

anvil (Metal)

Examples

K-1

with φ20mm Flat Contact & Anvil SK or AL.

with φ30mm Flat Contact & Anvil SK or AL.

with φ40mm Flat Contact & Anvil SK or AL.

with φ50mm Flat Contact & Anvil SK or AL.

K-3

with φ20mm Flat Contact & Anvil SK or AL.

with φ30mm Flat Contact & Anvil SK or AL.

with φ40mm Flat Contact & Anvil SK or AL.

with φ50mm Flat Contact & Anvil SK or AL.

K-2

with φ20mm Flat Contact & Anvil AL (SK is standard).

with φ30mm Flat Contact & Anvil SK or AL.

with φ40mm Flat Contact & Anvil SK or AL.

with φ50mm Flat Contact & Anvil SK or AL.

K-4

with φ20mm Flat Contact & Anvil SK or AL.

with φ30mm Flat Contact & Anvil SK or AL.

with φ40mm Flat Contact & Anvil SK or AL.

with φ50mm Flat Contact & Anvil SK or AL.

Optional φ20, 30, 40 and 50mm Contact Point and Anvils are available.

Please specify material for Contact Point and Anvil, Metal (SK) or Aluminum (AL).

第93页

Dial Pipe Gauges

92

6Dial Pipe Gauges Dial Lens Gauge /

Special gauges for measuring wall thickness of pipes.

Specifications

P-1

P-2

P-3

0.01

0.01

0.01

0~10

0~15

0~15

2.5

5.1

9.0

±20

±22

±22

10

15

15

10

50

50

1.8

1.8

1.8

L

D T

Graduation: 0.01mm

Range: 0~10mm

P-1

Graduation: 0.01mm

Range: 0~15mm

P-2

Graduation: 0.01mm

Range: 0~15mm

P-3

Sφ2

30

11

Sφ5

50

φ8.8

50

Model Graduation

(mm)

Range

(mm)

Accuracy

(µm) Minimum bore D Maximum wall thickness T

Pipe size measurable (mm)

Depth L

Measuring force

less than

(N)

Dial Lens Gauge

The dial lens gauge can measure convex,

concave, convexo-concave and any other

lenses in the same gauge by replacing the

two contact points and the anvil.

Graduation: 0.01mm

Range: 10mm

GL

maximum lens

diameter

measurable (mm)

maximum lens

thickness

measurable (mm)

GL 0.01 10 ±20 30 φ59 ※ 20 1.8

Specifications

Applied examples

a

φ3 steel ball

c

b

c

b

c

concave convex convexo-concave

Model Graduation

(mm)

Accuracy

(µm)

Range

(mm)

Throat depth

(mm)

Measuring force

less than (N)

Replaceable Flat contact point

(Standard accessory)

※ Anvil side is adjustable.

第94页

93

6

Dial Thickness Gauge (Special Order)

Dial Thickness Gauge (Special Order)

90 10

40

50

60

80 20

70 30

0

1

2

3

4 5 6

7

8

9 0

We manufacture with low or high measuring

force according to your needs.

● Maximum Measuring force under

2.4N (240gf)

● Minimum Measuring force over 0.4N

(40gf)

Please specify the desiredMeasuring force.

● Snap type

(Spindle is manually pushed down)

●For different applications, the shape of the contact point and anvil can be special ordered.

● For measuring thickness of hair

● For measuring thickness of paper

● Lever type (example of use)

① Both Contact Point and

Anvil needle type

② Both Contact Point and

Anvil ball type

④ Both Contact Point and

Anvil are horizontal blade

type

⑤ Both Contact Point and

Anvil are vertical blade

type

⑥ Needle type Contact

Point and Flat type Anvil.

⑦ Ball type Contact Point

and Flat type Anvil.

③ Both Contact Point and Anvil are

20mm diameter flat type

(also available inφ25 and 30mm)

Please specify φD

Please specify φD

and thickness.

Please specify φD

and thickness.

D = 10mm diameter

(also available inφ20, 25

and 30mm)

D = 10mm diameter

(also available inφ20, 25

and 30mm)

Please specify D

● Dial face with personal logo

● Special order dial faces

1.51.5

φD Sφ2.4 φD

1.51.5

1.51.5

φD φD Sφ2.4

0

9 1

8 2

7 3

6 4

5

world

1

2

3

4 5 6

7

8

9 0

Examples of modification for contact point and anvil

φD φD

第95页

Dial Thickness Gauges / Dial Lens Gauge / Dial Pipe Gauges

94

6Dial Pipe Gauges Dial Thickness Gauges / Dial Lens Gauge /

0

10

20

30

40

50 60

70

80

90

0 9

8

7

6 5 4

3

2

1

MADE IN JAPAN

MODEL G

SHOCK PROOF

3.5 21.2

2-φ10

120.7

43 10 4

20.2

39 24.7

0.01×10mm

JEWELED

17 3 80

5

60

40

13

60

40

70

30 14

20 16

15

0.01×20mm

12 8

50

50

11 10 9

G-2

7

6

4

70

30

80

20

90

10 10

90

19 18

0

0

0

2 1

33

4.5

φ10

77

35

90

80

70

60

50

40

30

20

10

0

4 6 5

0 1

3

2

9

7

8

0.01mm

2-φ10

34

18.3 32

30

φ10

0~30 22

27 18

LL-1

16.2

.4

MADE IN JAPAN

MODEL G-6C

.8

1.0

.6

SHOC R

.2

0

K P OOF

0.001mm

0 10 20

30

40

50

60

70

80 90 100 110 120

130

140

150

160

170

180 190

115.5

41.5

26.5 58.5

17

31

74

20

4 10

2-φ5

25 18

85

30

38

33

118

14

32

43.5

8.5 4

4

0.05mm

8

7

6

5

4

9 0 1

3

2

45

φ5.5

2

56.5

85

0.01mm

50

80

5

70 0

60 4

1

2

3

6

7

8

9

40

90 10 0

20

30

6 16 10 20

22 30 38 30

120

8

30 φ4

φ4

8

10

φ6

0

10

20

30

40

50

60

70

80

90

0 9

8

7

6 5 4

3

2

1

0

MADE IN JAPAN

SHOC K PROO F

0.01mm

60

38 22

φ4

30 18

9

90

80

70

60

50

40

30

20

10 0

4 6 5

0 1

3

2

9

7

8

0.01mm

27 18 30 9

84

10

φ2.3

50

Sφ5

3.5

18

90

80

70

60

50

40

30

20

10

0

4 6 5

0 1

3

2

9

7

8

0.01mm

84

27 18 30 9

φ8.8

φ2.3

50 18

G/G-0.4N/G-2.4N

G-6C

P-1

G-2

Q-1

P-2

G-3

GL

P-3

第96页

95

6 Dial Thickness Gauges / Dial Lens Gauge / Dial Pipe Gauges Dial Pipe Gauges Dial Thickness Gauges / Dial Lens Gauge /

H/H-0.4N/H-2.4N

H-3

J-A

J-B

H-2

HR-1

50

80 MODEL H

5

70 0

60 4

1

2

3

6

SHOCK

7

8

9

RO

40 P F O

0.01×10mm

JEWELED

MADE IN JAPAN

90 10 0

20

30

120

43 63.7

24.7

3.5

106.7

2-φ10

50

80

5

70 0

60 4

1

2

3

6

SHOCK

7

8

9

RO

40 P F O

90 10 0

20

30

0.01mm

15 23.5 43.5 41.5

3.5 7.5

170

240

50

80

5

70 0

60 4

1

2

3

6

7

8

9

40

90 10

0

20

30

0.01mm

15 23.5 48 41.5

7 7.5

170

240

0.01mm

8

5

2

3

4 6

7

0 1 9

90

80

70

60

50

40

30

20

10 0

11 22 17 17 46

48

70

2-7

NO.207 80 20

0.01mm

O

60

7030

40 5

3

4

50

50

7

6 SH

0

2

1 9

8

PR

40

60 CK

70

OO F

30

90

80

0

MADE IN JAPAN

10

0

10

90

20

Hv650以上

Hv550~700

51 39 57.5 44.25

6.5

φ20

φ10

150

0

1

2

3

4

5

6

7

8

9

0.05mm

J-B

MADE IN JAPAN

0

153.5

26 51 37 39.5

2.5 2.5

φ58

8

2-φ20

140

196

1.5

第97页

Dial Sheet Gauges

96

6Dial Sheet Gauges

K

60

7030

C

H

4

6

O

40

50

5

50

S

1

23

0

9

87

60

40F

30

ORP O 70

0.01mm

0

90

20

80 MADE IN JAPAN

NO.207

10

0

20

80

10

90

(238.5)

37 41 61

52

φ20

300

7 54

23

9

0

1

0.05mm

MADE IN JAPAN

87

6

K-25

4

0

206.5

37 41 52 37.1 39.4

2.5 2.5

2-φ20

300

404

3

8 5.4

NO.207 80 20

60 40 40

7030

PR

50

50

5

3

4

7

6

K

OC

SH

60

0

2

1

9

8

OOF

0.01mm

70

30

90 10

80

10

0

MADE IN JAPAN

90

0

20

φ10

φ10

φ5

φ20

7

φ66.5 φ58

225.3

27 41 55 61.3 41

500

506

590

190

84

2-φ25

55 43 43

8.8

φ10

190

3.5

209

8

5.4

590

27 41

500

506 84

0

0

2

1

3

4

0.05mm

K-45

8

9

7

6

MADE IN JAPAN

K-1

K-2

K-3

K-4

第98页

97

6

MEMO

第99页

Dial Upright Gauges

98

6 Rseries Dial Upright Gauges

Best suited for measuring precision parts and testing materials like rubber, leather, fabric and plastic etc.

Rubber, leather, urethane and film can be easily measured by this system.

● The table of R1 series are adjustable up and down by the nut installed side way.

● The dial gauge is affixed to the body.

Graduation: 0.001mm

Range: 2mm

Effective measuring range: 10mm

R1-A

Graduation: 0.01mm

Range: 10mm

Effective measuring range: 25mm

R1-B

Graduation: 0.01mm

Range: 20mm

Effective measuring range: 20mm

R1-C

Specifications

Dial Indicator (standard attachments)

Gauge installed Range (mm) Graduation (mm)

R1-A

R1-B

R1-C

25F-RE

107F-RE

207F-PL

2

10

20

±7

±15

±22

0.001

0.01

0.01

40

40

40

1.5

1.4

2.0

5

5

5

55

55

55

10

25

20

191

190

210

Total

height

(mm)

Measuring

depth

(mm)

Table

diameter

(mm)

Indication

error

(µm)

Effective

measuring

range(mm)

Contact

point dia.

(mm)

Measuring

force less than

(N)

Model

第100页

99

6Constant Pressure Thickness Gauges (Special Order)

● Constant Pressure Thickness Gauges can be made to comply with JIS by attaching exact weights that create the

specific pressures needed to measure different materials.

● Three types (FFG. FFA. FFD series) are available to meet your measurement.

Constant Pressure Thickness Gauges (Special Order)

Compact Handy type FFG series (PAT.No.3073347)

Specifications

FFG-1

FFG-2

FFG-4

FFG-5

FFG-6

FFG-7

FFG-8

FFG-9

FFG-11

FFG-12

0.001

0.001

0.01

0.01

0.01

0.01

0.01

0.01

0.01

0.01

2

2

10

7

10

10

10

10

10

10

±10

±10

±22

±22

±22

±22

±22

±22

±22

±22

24

24

24

24

24

24

24

24

24

24

5

5

10

5 (19.625mm2

)

8 (50.24mm2

)

5 (19.625mm2

)

8 (50.24mm2

)

35.7 (10cm2

)

25.2 (5cm2

)

16 (2cm2

)

30

30

30

30

30

30

30

40

30

30

1.25±0.15

(125±15)

less than 0.8

(less than 80)

less than 0.8

(less than 80)

0.2±0.04

(20±4)

0.51±0.1

(51±10)

0.44±0.1

(44±10)

1.13±0.26

(113±26)

less than 0.37

(less than 37)

less than 0.35

(less than 35)

less than 0.4

(less than 40)

5

5

7

5

7

5

7

25

20

15

Model Graduation

(mm)

Range

(mm)

Indication error

(µm)

Throat depth

(mm)

Contact Point dia

(ømm)

Anvil dia

(ømm)

Measuring force

N(gf)

Parallelism

(µm)

Shrink package film

Polyethylene package film

Ethylene film

Polyvinyl chloride film

Sheet Rubber

Vulcanized rubber / Thermoplastic rubber (Hardness 35IRHD less)

Vulcanized rubber / Thermoplastic rubber (Hardness 35IRHD less)

Vulcanized rubber / Thermoplastic rubber (Hardness 35IRHD more)

Vulcanized rubber / Thermoplastic rubber (Hardness 35IRHD more)

Urethane form

Common fabric (basic / fuzzy material)

Adhesive interlined cloth (common weave / common knit / non-woven)

Stockinet (common knit)

Unwoven / interlined cloth (old standard)

Adhesive interlined cloth (non-woven)

ZI709

ZI702

K6783

K6732

K6328

K6250A

K6250A

K6250A

K6250A

K6402

L1096

L1086

L1018

L1085

L1086

FFG-1

FFG-1

FFG-1

FFG-2

FFG-4

FFG-5

FFG-6

FFG-7

FFG-8

FFG-9

FFG-11

FFG-11

FFG-11

FFG-12

FFG-12

Measuring material JIS No. Applied Model

百万用户使用云展网进行期刊制作,只要您有文档,即可一键上传,自动生成链接和二维码(独立电子书),支持分享到微信和网站!
收藏
转发
下载
免费制作
其他案例
更多案例
免费制作
x
{{item.desc}}
下载
{{item.title}}
{{toast}}